Product Categorie: Kalibrier-Lichtquellen
Avantes provides numerous plasma calibration light sources for the wavelength calibration of a spectrometer. Using their characteristic spectral lines, the calibration curve can be adapted from pixel number to wavelength of a spectrometer. The AvaSoft Full (??) provides a function that makes it very easy to correct the calibration curve. However, the corrected curve is […]
The AvaLight-DH-CAL is suitable for absolute calibrations to spectral irradiance in the UV and visible range (200-1099 nm). As with the AvaLight-HAL-CAL-Mini, the NIST traceably calibrated irradiance refers to the surface of the removable cosine corrector, which can be connected to an optical fiber via an SMA connector. The calibration data are supplied in ASCII […]
This absolutely calibrated halogen light source is ideally suited for spectral calibration to irradiance in the wavelength range from 350 nm to 1095 nm. Optionally, the calibrated NIR wavelength range from 1100 nm to 2500 nm can be ordered. The spectral irradiance is absolutely calibrated on the removable cosine corrector, which can be connected to […]
This 1000 W tungsten-halogen light source produces an absolutely calibrated irradiance of 250 nm to 2500 nm. It can be configured as a simple lamp, but it bears the ANSI designation and is calibrated to the 2000 NIST Irradiance Scale, or together with numerous accessories such as a lamp holder, an alignment jig, a lamp […]
The RS-50 VF is mainly used to generate homogeneous irradiance at a distance of 6 to 30 meters or for illumination of areas with up to 50 cm in diameter. The light source is absolutely calibrated for a fixed distance. From a distance of approx. 6 metres, the RS-50 VF can be regarded as a […]
The RS-12DN is a NIST traceable white light standard for radiance or luminance. Using a separate filter, the unit can be converted to a light source for NVIS display simulation. This simulates green light from cockpit displays and additionally outputs a certain level in the NIR range to which a spectroradiometer or radiometer can be […]
This precision halogen light source is absolutely calibrated for irradiance and illuminance and is often used for the calibration of light measuring instruments or optical detectors, spectroradiometers, radiometers or spectrometers. In combination with the RS-70-X extension, the RS-10D light source can also be used as an absolute standard for spectral luminance, luminous intensity, radiance or […]
These precision halogen light sources are absolutely calibrated for radiation flux and are mainly used for the calibration of integrating spheres, light measuring devices and as excitation for detectors. The power can be selected between 5 W and 100 W. The RS-15 is thus a NIST traceable standard for spectral radiant flux or luminous flux […]