Product Categorie: PHOTONIK ZUBEHÖR
Fiber Control’s MPC1 series of motorized polarization controllers are ideal for use in WDM applications. Following the Lefèvre loop design they enable stable and rapid control of the state-of polarization of laser sources without altering the time-averaged power. Models with 1, 2 and 4 channels are available. They can be equipped with various fibers for applications […]
The manual polarization controllers by Fiber Control make use of stress-induced birefringence to change the polarization state in the inserted fiber. Complete coverage of the Poincaré sphere is achieved by adjusting the paddles. Different versions are available, both with and without inserted fiber. Model FPC-1 is designed to be used with either 250 um bare fibers […]
Gulf Photonics is a specialist in manufacturing and assembling. The company focuses on special fibers for medicine, aerospace, semiconductors and spectroscopy. Another domain of Gulf Photonics are their special UV ESR fibers which are specified from 190nm – 800nm. Other fibers or probe types such as UV/SR fibers (200nm – 1100nm) or broadband fibers (200nm […]
The original Beck/Ealing reflecting objectives were originally developed for microscopy and are only offered by a few manufacturers worldwide. They are based on a two-mirror system and, unlike refractive objectives, are free of chromatic aberration. The reflecting objectives are a combination of mirror and lens and consist of primary and secondary mirrors for light focusing […]
For optimal use of First Contact™ Cleaning Polymer, the manufacturer offers a wide range of proven accessories. Please call us if you have any questions regarding your specific application. Applying First Contact™ The brush integrated in the screw cap of the applicator bottle is sufficient for applying First Contact™ solution to surfaces up to 30 mm […]
Using cleaning polymer First Contact™ is THE modern way to clean dirty optics gently and without any residues. Furthermore the dry polymer film protects your optics effectively against dirt and damage during storage and transport. For smaller optics we recommend First Contact™ solution which comes along in kits with an applicator bottle with integrated brush. […]
Mountain Instruments offers achromatic optics that can be adapted exactly to customer-specific requirements. These include various coatings, mirrors, lenses, windows, prisms, polarization optics, UV and IR optics as well as optical filters. Achromatic lenses are used to minimize or eliminate chromatic aberration. In addition, achromatic design can also be used to reduce spherical aberrations. An […]
The convex optics of Mountain Instruments can be tailored exactly to customer-specific requirements. We offer various coatings, mirrors, lenses, windows, prisms, polarization optics, UV and IR optics as well as optical filters. Depending on the application, we have flat and biconvex optics. Plano-convex optics These lenses focus parallel beams onto a light spot. The spot […]
Mountain Instruments offers concave optics that can be tailored to specific customer requirements. These include various coatings, mirrors, lenses, windows, prisms, polarization optics, UV and IR optics and optical filters. In the field of concave optics, we distinguish between bi- and plano-concave optics. Plano-concave optics Plano-concave lenses convert incident parallel beams into divergent beams. Like […]
Avantes provides a wide choice of optical fibers. All of them are multi-mode fibers with a fiber diameter of 8 µm to 1000 µm. The core consists of silicon dioxide. The following core diameters are available: 8 µm (only for IR fibers, 200 – 800 nm) 50 µm (only for UV or IR fibers, 200 […]
An integrating sphere is used to homogenize the wavelength and radiance of light from a specific source. For this purpose, a sphere is used whose inner surface reflects as efficiently and diffusely as possible, so that maximum homogenization is achieved by multiple internal reflection. Avantes provides the AvaSphere-xx-REFL in three different sizes (30, 50 and […]
Super Cold Filters from Asahi Spectra are heat-reflecting filters that are much more efficient than conventional heat-absorbing filters. This means that the substrate (quartz glass) is not damaged even with a high-power light source. Overview of the standard Super Cold Filter products Round with a diameter of 25mm square 50x50mm Customized filters with different specifications […]
Long-pass filters are usually used to isolate areas of a broad spectrum. The purpose of this type of filter is to allow wavelengths above the specified cut-off wavelength to pass and to block wavelengths below the cut-off wavelength. Long-pass filters can provide the desired individual wavelength range in combination with a corresponding short-pass filter. Asahi […]
Neutral density filters are reflective ND filters that are used to diffuse light intensity. The coated chrome film reduces the light by mainly reflecting and partially absorbing it. Asahi’s ND filters are designed to provide uniform spectral performance, particularly in the VIS range, without changing the relative spectral distribution of energy. Nevertheless, they are available […]
Besides light sources, optical fibers and spectrometers, Integrating spheres are an often used instrument for various light mesaurement tasks. The diffuse multiple reflexion of light inside the integrating spheres generates a constant radiance in any direction as well as a homogenization of single wavelenthgs. That means an integrating sphere can be used for example approximately […]
Quantum Northwest offers a wide range of temperature controlled single and multi-cell holders for many applications. Choose from a wide variety of stand-alone units or select a specific cell holder for your existing spectrometer. They are available to fit all major spectrometers like by Agilent, Aimil Chirascan, Aminco-Bowman, Dynamica, Edinburgh Instruments, Hitachi, Horiba, IBH, ISS, […]
Short-pass filters are generally used to isolate areas of a broad spectrum. The task of this type of filter is to allow wavelengths below the output cut-off wavelength to pass and to block wavelengths above the cut-off wavelength. Short-pass filters can provide the desired wavelength range in combination with a corresponding long-pass filter. Asahi Spectra […]
Bandpass filters are typically used to pass a well-defined wavelength band of the spectrum while suppressing both the long and short wavelength sides of the transmission band. Our coating designs are based on multiple cavity resonators. As a result, our bandpass filters have very steep slopes and very high attenuation outside the narrow 10 nm […]
Avantes offers various cuvette holders suitable for fiber optic spectrometers, but also for many other applications. Holder for 10×10 mm standard cuvettes: for absorption measurement: CUV—UV/VIS for fluorescence measurement: CUV-UV-FL-UV/VIS for absorption and fluorescence measurement: CUV-ALL-UV/VIS for direct mounting to an AvaLight light source: CUV-DA-xxx for direct mounting to an AvaLight light source with integrated filter holder and […]